Tripp Lite series SmartOnline 5000VA 4500W 208V Online Double-Conversion UPS - L6-30P, 2 L6-20R, 2 L6-30R, Hardwired Output, Network Card, Extended Run, 3U Rack/Tower
| Product Name | 
                                                Eaton Tripp Lite series SmartOnline UPS
                                             | 
| Catalog Number | 
                                                SU5000RT
                                             | 
| UPC | 
                                                786689811723
                                             | 
| Product Length/Depth | 
                                                25.04 in
                                             | 
| Product Height | 
                                                5.12 in
                                             | 
| Product Width | 
                                                17.32 in
                                             | 
| Product Weight | 
                                                114.02 lb
                                             | 
| Compliances | 
                                                FCC Compliant  CE Marked RoHS FCC Class A ENERGY STAR certified REACH | 
| Certifications | 
                                                NOM  IEC/EN 62040-2 CSA 22.2 UL 1778 cTUVus | 
| Topology | 
                                                Online/Double-conversion
                                             | 
| Form factor | 
                                                Rack/tower
                                             | 
| Rack size | 
                                                3U
                                             | 
| Color | 
                                                Black
                                             | 
| VA rating | 
                                                5000 VA
                                             | 
| Wattage | 
                                                4500 W
                                             | 
| Rack mounting kit | 
                                                Yes
                                             | 
| Package contents | 
 | 
| Surge protection | 
                                                Yes
                                             | 
| Internal bypass | 
                                                Yes
                                             | 
| Current Crest Ratio | 
                                                3:1
                                             | 
| Input connection | 
                                                Hardwire; L6-30P
                                             | 
| Input cord length | 
                                                10 ft
                                             | 
| Input nominal voltage | 
                                                200 VAC/208 VAC/220 VAC/230 VAC/240 VAC
                                             | 
| Nominal frequency | 
                                                50/60 Hz
                                             | 
| Input frequency range | 
                                                50/60 Hz
                                             | 
| Input power factor | 
                                                >0.99 typical
                                             | 
| Receptacle | 
                                                (2) L6-20R; (2) L6-30R; Hardwire
                                             | 
| Number of Outputs L6-20R | 
                                                2
                                             | 
| Number of Outputs L6-30R | 
                                                2
                                             | 
| Number of outputs hardwired | 
                                                1
                                             | 
| Output waveform | 
                                                True sine wave
                                             | 
| Voltage | 
                                                208 V
                                             | 
| Output nominal voltage | 
                                                208V default (200/208/220/230/240V)
                                             | 
| Runtime graph |  | 
| Battery replacement | 
                                                EBP-1803
                                             | 
| Battery type | 
                                                Valve Regulated Lead Acid (VRLA)
                                             | 
| Extended battery capability | 
                                                Add up to 4 extended battery modules (EBM). Part number BP180RT
                                             | 
| Standard factory warranty | 
 | 
| Extended service plans | 
 | 
| Runtime at half load | 
                                                11 min
                                             | 
| Ethernet interface | 
                                                Yes
                                             | 
| Includes network card | 
                                                Yes
                                             | 
| Software compatibility | 
                                                PowerAlert
                                             | 
| Altitude | 
                                                <1000m for nominal power, 10% power degrading every 1000m (up to 3000m)
                                             | 
| Noise level | 
                                                <45 dB at 1 meter
                                             | 
| Relative humidity | 
                                                0-95% non-condensing
                                             | 
| Front Panel LCD Display | 
                                                LCD graphical display
                                             | 
| Input Plug Type | 
                                                NEMA L6-30P
                                             | 
| Output Receptacles | 
                                                L6-30R  L6-20R Hardwire | 
| Product Features | 
                                                Emergency Power Off (EPO)/Remote On-Off (ROO)  Expandable Runtime L6-30P 10ft. | 
| Product Highlights | 
                                                Protects equipment against blackouts, brownouts, transient surges and line noise  Keeps equipment running during outages to allow time for file saves and safe shutdown Pre-installed WEBCARDLXE network card enables full remote access and control Menu-driven LCD interface keeps you updated on critical load information in real time Optional extended battery modules allow extended runtime to keep equipment powered | 
| PowerAlert Software | 
                                                For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
                                             | 
| Network Management Cards | 
                                                WEBCARDLXE
                                             | 
| Network Management Cards Details | 
                                                Network management card included
                                             | 
| Efficiency at max. load | 
                                                93%
                                             | 
| Input voltage range | 
                                                200-240V
                                             | 
| Max number of battery packs | 
                                                4
                                             | 
| Output frequency | 
                                                50/60 Hz
                                             | 
| Output power factor | 
                                                0.9
                                             | 
| Phase (input) | 
                                                Single-phase
                                             | 
| Runtime at full load | 
                                                3 min. (4500W)
                                             | 
| Communication interface | 
                                                USB and DB9 serial cables included  USB Contact closure RS-232 Included network card | 
| Battery Access | 
                                                Battery access door
                                             | 
| Typical Battery Runtime | 
                                                Expandable Runtime
                                             | 
| Dc Voltage | 
                                                180
                                             | 
| Operating Temperature Range | 
                                                32° to 104°F (0° to 40°C)
                                             | 
| Communications Cable | 
                                                USB and DB9 serial cables included
                                             | 
| Input Circuit Breakers | 
                                                Recommended 30A upstream
                                             | 
| Optional Mounting Accessory Notes | 
                                                2 post rail kit available, part # RK2PC
                                             | 
| Output Circuit Breakers | 
                                                20A breaker protects L6-20R outlets
                                             | 
| High Voltage Transfer to Battery Power | 
                                                276V
                                             | 
| Low Voltage Transfer to Battery Power | 
                                                176V
                                             | 
| Application | 
                                                Mission Critical Applications
                                             | 
| Switch configuration | 
                                                RPO / ROO
                                             | 
| AC suppression joule rating | 
                                                390
                                             | 
| Housing material | 
                                                Metal
                                             | 
| Output AC waveform (AC mode) | 
                                                Pure Sine wave
                                             | 
| Output AC waveform (battery mode) | 
                                                Pure sine wave
                                             | 
| Output Capacity (kVA) | 
                                                5
                                             | 
| Output Capacity (kW) | 
                                                4.5
                                             | 
| Output Capacity (VA) | 
                                                5000
                                             | 
| Operating Elevation | 
                                                <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters) at 40°C
                                             | 
| AC Suppression Response Time | 
                                                0 ms
                                             | 
| Alarm Interface | 
                                                Press ESC to silence the alarm
                                             | 
| Audible Alarms | 
                                                Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions
                                             | 
| Battery Start Capability | 
                                                Cold-start operation supported
                                             | 
| Cooling Method | 
                                                Fan
                                             | 
| Battery Replacement Description | 
                                                Hot-swappable, user replaceable batteries. UPS requires 1 Replacement Battery Cartridge.
                                             | 
| LED Indicators | 
                                                4 status-indicating LEDs
                                             | 
| Frequency Rating Details | 
                                                50 or 60Hz, autosensing or configurable as a frequency converter
                                             | 
| Minimum Required Rack Depth With External Battery Pack | 
                                                31
                                             | 
| Output Voltage Regulation (Line Mode) | 
                                                +/- 1%
                                             | 
| Output Voltage Regulation(Battery Mode) | 
                                                +/- 1%
                                             | 
| Recommended Electrical Service | 
                                                30A
                                             | 
| Storage Temperature | 
                                                With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
                                             | 
| Included Mounting Accessory Description | 
                                                Includes 4 post rackmount and tower pedestal accessories
                                             | 
| Input Nominal Voltage Description | 
                                                Factory configured to 208V
                                             | 
| Network Monitoring Port Description | 
                                                WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX
                                             | 
| Nominal Voltage Details | 
                                                200V, 208V, 220V, 230V, 240V
                                             | 
| Voltage Regulation Description | 
                                                Online, double-conversion power conditioning
                                             | 
| Plug Type | 
                                                NEMA L6-30P
                                             | 
| Maximum Input Amps | 
                                                23
                                             | 
| Minimum Required Rack Depth (cm) | 
                                                78.74
                                             | 
| Minimum Required Rack Depth (inches) | 
                                                31
                                             | 
| Total Harmonic Distortion | 
                                                < 2% THDV on linear load; < 5% THDV on non-linear load
                                             | 
| UPS Input Cord Length (m) | 
                                                3.1
                                             | 
| Power Mode Transfer Time | 
                                                0 ms
                                             | 
| Optional Accessories | 
                                                2 post rackmount (RK2PC)
                                             | 
| EMI AC Noise Suppression | 
                                                EMI / RFI AC Noise Suppression
                                             | 
| UPS Input Connection Type | 
                                                Hardwire  L6-30P | 
| External Battery Pack Compatibility | 
                                                BP180RT
                                             | 
| Green Energy-Saving Features | 
                                                High efficiency economy mode operation
                                             | 
| High Availability UPS Features | 
                                                Automatic voltage regulation (AVR)  Hot swappable batteries On-Line/Double-Conversion Remote management Expandable battery backup Pure sine wave output Zero transfer time Surge/noise protection |