| Catalogue number | Rack size | Power rating (VA/watts) | Default AC input/output voltage | Maintenance bypass | Efficiency (online) | Input connection (HW = hardwired) | Output connections (HW = hardwired) | Unit dimensions (hwd) and weight | 
|---|
| 9PX3K3UNP1G2 | 6U | 3000/3000 | 208V/208V + 120V | Included | 0.96 | L6-30P, 10 ft. | (1) L6-30R + (6) 5-20R + (1) L14-30R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX3K3UNP1G2 bundle includes: 9PX3K3UG2 UPS + 9PXPPDM1G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX3K3UNP2G2 | 6U | 3000/3000 | 208V/208V + 120V | Included | 0.96 | HW | HW | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX3K3UNP2G2 bundle includes: 9PX3K3UG2 UPS + 9PXPPDM2G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX3K3UNTF5G2 | 6U | 3000/3000 | 208V/208V + 120V | Optional | 0.96 | HW or L6-30P, 10 ft. | (1) L6-30R + (2) L6-20R + (18) 5-20R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX3K3UNTF5G2 bundle includes: 9PX3K3UG2 UPS + 9PXTFMR5G2 step-down transformer. See below for transformer description. | 
| 9PX5KP1G2 | 6U | 5000/5000 | 208V/208V + 120V | Included | 0.96 | L6-30P, 10 ft. | (1) L6-30R + (6) 5-20R + (1) L14-30R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX5KP1G2 bundle includes: 9PX5KG2 UPS + 9PXPPDM1G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX5KP2G2 | 6U | 5000/5000 | 208V/208V + 120V | Included | 0.96 | HW | HW | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX5KP2G2 bundle includes: 9PX5KG2 UPS + 9PXPPDM2G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX5KTF5G2 | 6U | 5000/5000 | 208V/208V + 120V | Optional | 0.96 | HW or L6-30P, 10 ft. | (1) L6-30R + (2) L6-20R + (18) 5-20R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX5KTF5G2 bundle includes: 9PX5KG2 UPS + 9PXTFMR5G2 step-down transformer. See below for transformer description. | 
| 9PX6KP1G2 | 6U | 6000/5400 | 208V/208V + 120V | Included | 0.96 | L6-30P, 10 ft. | (1) L6-30R + (6) 5-20R + (1) L14-30R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX6KP1G2 bundle includes: 9PX6KG2 UPS + 9PXPPDM1G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX6KP2G2 | 6U | 6000/6000 | 208V/208V + 120V | Included | 0.96 | HW | HW | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX6KP2G2 bundle includes: 9PX6KG2 UPS + 9PXPPDM2G2 PPDM with integrated maintenance bypass. See below for PPDM description. | 
| 9PX6KTF5G2 | 6U | 6000/5400 | 208V/208V + 120V | Optional | 0.96 | HW or L6-30P, 10 ft. | (1) L6-30R + (2) L6-20R + (18) 5-20R | 10.2 x 17.3 x 27 in., 203 lb. | 
| 9PX6KTF5G2 bundle includes: 9PX6KG2 UPS + 9PXTFMR5G2 step-down transformer. See below for transformer description. | 
| 9PX8KMG2 | 4U | 8000/8000 | 208V | Included | 0.965 | HW | HW + (4) L6-30R | 6.8 x 17.3 x 32.6 in., 188.7 lb. | 
| 9PX8KMG2 bundle includes: 9PX8KG2 UPS + MBP11K208G2 maintenance bypass module. See below for bypass description. | 
| 9PX8KTF5G2 | 7U | 8000/8000 | 208V/208V + 120V | Included | 0.965 | HW | HW + (3) L6-30R + (18) 5-20R | 12 x 17.3 x 32.6 in., 315 lb. | 
| 9PX8KTF5G2 bundle includes: 9PX8KG2 UPS + 9PXTFMR5G2 step-down transformer + MBP11K208G2 maintenance bypass module. See below for transformer and bypass description. | 
| 9PX11KMG2 | 4U | 11000/11000 | 208V | Included | 0.97 | HW | HW + (4) L6-30R | 6.8 x 17.3 x 32.6 in., 188.7 lb. | 
| 9PX11KMG2 bundle includes: 9PX11KG2 UPS + MBP11K208G2 maintenance bypass module. See below for bypass description. | 
| 9PX11KTF11G2 | 7U | 11000/11000 | 208V/208V + 120V | Optional | 0.97 | HW | HW + (8) 5-20R + (2) L14-30R + (4) L6-30R | 12 x 17.3 x 28.6 in., 377 lb. | 
| 9PX11KTF11G2 bundle includes: 9PX11KG2 UPS + 9PXTFMR11G2 step-down transformer. See below for transformer description. | 
| 9PX11KTF11MG2 | 7U | 11000/11000 | 208V/208V + 120V | Included | 0.97 | HW | HW + (8) 5-20R + (2) L14-30R + (4) L6-30R | 12 x 17.3 x 32.6 in., 392 lb. | 
| 9PX11KTF11MG2 bundle includes: 9PX11KG2 UPS + 9PXTFMR11G2 step-down transformer + MBP11K208G2 maintenance bypass module. See below for transformer and bypass description. | 
| 9PX11KTF5G2 | 7U | 11000/11000 | 208V/208V + 120V | Included | 0.97 | HW | HW + (3) L6-30R + (18) 5-20R | 12 x 17.3 x 32.6 in., 315 lb. | 
| 9PX11KTF5G2 bundle includes: 9PX11KG2 UPS + 9PXTFMR5G2 step-down transformer + MBP11K208G2 maintenance bypass module. See below for transformer and bypass description. |